Recently I'm writing a simple program to download g-code to a PLC device ,which is based on Modbus RTU.But I can't figure which CRC code is the right one.
Address is "02",function code is"0x7A",g-code string (hex) is "4E303020473030205831302E30205931302E300D"(ascii mode of "N00 G00 X10.0 Y10.0(Enter)").
The PLC Manual shows that CRC code is "578E",but almost softwares shows "42FD".How can I calculate the right one?
manual photo:
https://mmbiz.qlogo.cn/mmbiz/icVMts8g1VicuveK36HJzInQW3cicVBTDINBeNYyZrMSSbO6dlZ8DMf258ESTibIansmhhEl7icnhuy4Dv9KeQnfkow/0?wx_fmt=png
software photo:
https://mmbiz.qlogo.cn/mmbiz/icVMts8g1VicuveK36HJzInQW3cicVBTDINtHs6My1hs4kySSjsicVNNQU0gH6AHiaklLTZzS2jj9mu7xqjBReJoA4g/0?wx_fmt=png
Related
I've been exploring the ADAM 6717 from Advantech.
This is the ModBus address table for said device:
At first I wanted to modify the value of the Digital output channel 0(DO0), so, as can be seen from the picture above, such address is the 0x0017.
I succeed at this by using a ModBus tool and the following settings:
Sending either "On" or "Off", turns On and off a LED connected to that output. Everything runs smoothly according to my expectation up to this point.
The problem arises when I want to read the Analog Input channel 6 or equivalently, address 400431~40044.
Since that address lies on the Analog Output Holding Registers part of the address table, I though that the following settings would accomplish the job:
However, as can be seen above, the reading shows 0.0 when there is actually 6V connected to that input (a potentiometer)
It is worth mentioning that I've made sure to enable the AI6 channel as well as setting it to Voltage mode instead of current. Also, the web utility for the device shows the AI6 reading correctly as I change the potentiometer's resistance value.
So the problem doesn't lie in the connection from the potentiometer to the AI6 but somewhere else.
Out of nothing and leaving aside what I think I know on this topic, I though of changing the function from 0x03 to 0x04
However, the response is exactly the same.
It bugs me that I can read and write values to the output coils but not the Analog output holding registers.
Is there any configuration that I might be missing over here?
Thanks in advance.
Device settings:
IP address: 10.0.0.1
Port in which the ModBus service is running: 5020
For a fast ADC sampling USB device, I am using the USB 2.0 High Speed capable STM32F733 with the embedded USB-HS PHY. In USBView, I can see that the device is enumerated, the libusb code opens the device and claims interface, but when I try to receive data with libusb_bulk_transfer, the operation times out (return code -12). Things I have tried: I have confirmed than when I request data with libusb_bulk_transfer, the device is interrupted. Note: I have DMA enabled in my class configuration C file and it is not clear to me how that is triggered. I have verified that the transfersize and packet count registers are being set correctly by the LL library function, and that when I request data from
Any tips on debugging such problems will be much appreciated - this board is my undergrad thesis due in under two months!
Desktop sequence:
libusb_get_device_list, libusb_get_device_descriptor, libusb_open, libusb_get_string_descriptor_ascii, libusb_free_device_list, libusb_bulk_transfer(devh, fat_EPIN_ADDR, inframe, fat_EPIN_SIZE, &gotBytes, 100). Where gotBytes is integer, and inframe is a large array.
Device firmware:
MX_USB_DEVICE_Init();
uint8_t txBuffer[10*fat_EPIN_SIZE];
while (1)
{
USBD_LL_Transmit(&hUsbDeviceHS, Custom_fat_EPIN_ADDR, txBuffer, Custom_fat_EPIN_SIZE);
HAL_Delay(1);
}
Custom_fat_EPIN_SIZE is 0x200 and the endpoint address is 0x81 (EP IN 1)
Installed driver for device is WinUSB (verified in Device Manger to be winusb.sys), and I am linking libusb-1.0 into my desktop program. You can find my source code at https://gitlab.com/tywonemi-school-stuff/silicon-radar-fun, the firmware is My SW/v1 and the desktop software is a Qt Creator project in My SW/Viewer, of note is usb.cpp. You can also compare with testing project/HIDTest, which is code that I tested with STM32F303 nucleo dev board where I was able to read an array through IN bulk endpoint with the Viewer application. However, F3 has the USB peripheral, while F7 has OTG_USB, and I am now attempting USB 2.0 compliant HS so there may be more protocol-based pitfalls. You can also find the output of the device descriptor etc from USBView in my SW/USBView_broken.txt
EDIT 1: I have found finally some concrete error in the STM32 behavior. The DMAADDR is set for EPIN 0x81, and never increments, despite the DMA being enabled. I have went through literally every occurrence of the word "DMA" in the USB_OTG periphery.
I thought it might be that my linker script makes my array be stored in DTCM or similar, and the OTG DMA can't access it, but the address of txBuffer is 0x2003EBEC which is in SRAM2. The AHB matrix in the reference manual clearly shows, that the USB OTG HS DMA is master for a bus that SRAM2 is a slave of. And DTCM is connected too. I will look for application notes for USB OTG HS DMA - it just seems to be refusing to copy data!
I have fixed my issue by disabling the DMA setting. I have re-read the relevant portions of the reference manual and still don't know how exactly the values propagate into the Tx FIFOs. It is possible that DMA-less operation will be a major bottleneck in my project, I might return to this later.
I have a Verilog code simulated and synthesized on ISE design toolkit. I've got an FPGA spartan 6 device which is to be used for the implementation. But there is a problem with the device (probably a power issue) which makes the device unavailable in any of the COM ports when I connected it to my PC. So I want to check whether my Matlab code which I made for serial communication through the device does the desired job. So I need a method to test serial communication via any of the COM ports without connecting a serial com device to the PC. Is there any such method that I can Tx Rx serial data from Matlab to COM ports? Any software or any other method would be highly appreciated :)
I found a way to test Matlab serial communication using virtual serial ports.
Download "Freeware Virtual COM Ports Emulator" from: http://freevirtualserialports.com/
I installed it in Windows 10, and it's working (as trial).
Add a pair of two serial ports:
Execute the following Matlab code sample to verify it's working:
s3 = serial('COM3','BaudRate',115200);
s4 = serial('COM4','BaudRate',115200);
fopen(s3);
fopen(s4);
fwrite(s3, uint8([1, 2, 3, 4, 5]));
%fprintf(s3, '12345');
pause(0.1);
RxBuf = fread(s4, 5)
fclose(s3);
delete(s3);
clear s3
fclose(s4);
delete(s4);
clear s4
The output is:
RxBuf =
1
2
3
4
5
Bypassing the problem "it only stays for a single test session".
There is a problem when creating a pair of virtual ports using the software, it only stays for a single test session.
I guess it's a problem with the COM port emulation software.
The following solution, is not a good practice (and not a true solution).
Declare the serial object as global, keeping the object persistent.
Create the serial object only if it's not created.
Don't delete and don't clear the serial object.
See the following code sample:
global s3 s4
if isempty(s3)
s3 = serial('COM3','BaudRate',115200);
end
if isempty(s4)
s4 = serial('COM4','BaudRate',115200);
end
fopen(s3);
fopen(s4);
fwrite(s3, uint8([1, 2, 3, 4, 5]));
pause(0.1);
RxBuf = fread(s4, 5)
fclose(s3);
%delete(s3);
%clear s3
fclose(s4);
%delete(s4);
%clear s4
You can also look for a better virtual COM port software.
As Rotem suggested, if you need to communicate via serial line between 2 program of your PC you need a virtual COM port emulator.
It seems you are running on Windows OS so I would recommend a completely free emulator (not a trial one). For Windows I use com0com Null-modem emulator (from SourceForge).
In the example below I will show how to communicate with "another" device so Matlab will not handle both side of the communication. The other device will be simulated by a simple terminal. For windows I use RealTerm: Serial/TCP Terminal (also from SourceForge).
Setup:
Execute the setup of both program with all default options. by default com0com will create a virtual pair COM3/COM4 but if these port already exist on your system the program may assign other numbers. Check the numbers before you run the example. (it will also create a CNCA0/CNCB0 pair but you can ignore this one for now).
For RealTerm, once installed (don't forget to activate the server registration at the end of the setup, it should be ticked by default though), it will look like below. Keep all default options, just set the port number and the baud rate if they need to be changed.
Test MATLAB -> Terminal
You are ready to send Ascii characters or binary values from MATLAB to your device. The animation below shows you an example of both option:
you can click on the picture to see it full size. It is running in loop so you may want to wait until it restart from the beginning.
Test Terminal -> MATLAB
Below animation shows you how to test the communication in the other way:
Don't forget to tick [CR] [LF] on RealTerm when you send Ascii characters and want to use the '%s' format specifier on MATLAB, as it needs these characters to detect the end of the string.
Note:
If you have another terminal program that you are more used too, it
will work the same.
If the RealTerm option does not suit you, or if you want to handle
both sides of communication from Matlab, then you can use the code
provided by Rotem in his first answer. Just install com0com but
ignore all the RealTerm part.
What is the Difference between BGAPI and BGScript ?
And if we write any code for BG profile than how can we burn it in BLE 112?
The BGAPI interface defines the protocol used to talk to the module over USB or serial link.
BGScript is something which runs on the module processor itself, when the USB or serial link is not used.
I have the dongle, BLED112, which is the same thing as BLE112 with a USB connector on it, and the code is "burned" to it using standard USB DFU interface.
The downloading of the code to BLE112 can be done using several methods:
(1) Bring out the DD, DC debug interface pins from your module and use the CC-Debugger (digikey part 296-30207-ND, $55). This works every time. If you have the DKBLE112 kit, the CC-Debugger fits on the 10-pin .050 connector in lower right corner. You can "burn" any firmware and any stack this way. Works awesome.
(2) Hope that the current firmware on the CC2540 has serial bootloader, and load the new firmware (hopefully also containing serial bootloader) using UART. TI has the tools, but it sure seems quite convoluted to me, and I did not try it.
I have an Arduino with a WiFly shield, everything works perfectly!
The thing is, when I want to turn on an LED, I open in my
webbrowser:
192.168.1.120/ledon/
(I made a program which handles this URL).
But the thing is; when I make a request, I must wait 1-2 seconds before I can do another one.
So, it is very long, and if I want to control motors, it is just too long.
So, instead of using an HTTP request, I want to use something else which can be faster.
Something "super fast".
I just need to tell the Arduino:
- go direction 1
- go direction 2...
- turn on LED
- turn off LED
- tell me the light level (which return a int)
So it is just about a small amount of data.
Can you show me a way? (Telnet, UDP, OSC?)
For your arduino, have a look at just using sockets or even encoding the data in the URL requested.
You shouldnt get less than about 0.8 Seconds Lag maximum.
How big is your program for handling the Url /ledon/ ?
Using pure packets (usually TCP) from your computer to the arduino is faster sometimes..
But you may need to code a application to handle the packets on the pc.
There is the option of Javascript to parse data back and forth e.g. reading the light level and such.