In SAP HANA index server and statistics server stopped suddenly and not running.
I tried to stop and restart the server by the following commands.
HDB stop
HDB start
But still it is not working. Does anyone know what causes this problem and what is the solution? Thanks in advance.
If the indexserver doesn't start, you cannot logon as SYSTEM (or any other user for that matter). A good way to find out what the reason for the failed start is to check the tracefile for the nameserver, the indexserver and the statisticsserver.
Logon as <sid>adm and change to the tracefile folder via cdtrace.
Then find the tracefiles and use e.g. less to read through them to find the actual error messages.
Alternatively you can use SAP HANA Studio with the emergency connection to review the trace files without terminal access.
Related
I've been using Mongo for a while now, and I never had any kind of errors. But today, I tried running the mongo command in my terminal and I got the following error:
Error connecting to 127.0.0.1:27017 :: caused by :: No connection could be made because the target machine actively refused it. :
I have my PATH variable for Mongo properly configured in my environment variables as follows:
C:\Program Files\MongoDB\Server\4.4\bin
so I doubt that is the issue. I remember going through my task manager yesterday and I accidentally terminated a program running in the background related to Mongo, but I can't seem to remember exactly what it was called, and I really think that that's the root of my problem, because before having terminated that Mongo program in my task manager I had never ran across this connection problem before.
By terminating a program in the background, I'm going to assume you didn't just end process, otherwise a simple computer restart would fix your issue. And in some cases, that same program would've relaunched when you launched MongoDB. But if you disabled a service and need to find which service needs to be running to be able to connect to your MongDB then I would suggest going through your Windows Services list and seeing which ones you disabled and looking one relating to TCP or SNMP.
This is because MongoDB Wire Protocol is a simple socket-based, request-response style protocol. You communicate with the database server through a regular TCP/IP socket and since you can't remember which one you "terminated" and any number of services related to networking can cause a dependency to be absent, I can't be more specific in helping you determine which one you need to turn back on and you'll have to do it through trial and error but I can at least offer you some guidance, hopefully.
Specifically you can either
Run system configuration using
msconfig
In a run box, navigating to the Services tab, order the list by Date Disabled to find the service that was disabled which correlates with when you when snooping through task manager, or
Run Task manager and navigate to the Services Tab, then Open Services, and order them by Status or by Name, and look for any service that includes TCP/IP, COM+, Port direction, etc. to see which one is disabled and change the configuration from anything but Disabled and then stat it manually and run MongDB again.
It's about as specific as I can get without knowing anything more than you terminated some program running in the background but I hope it helps.
The background process (daemon) for MongoDB is called 'mongod'. It's an executable in your bin directory inside your mongodb installation. You can just execute it in the terminal.
Run:
C:\Program Files\MongoDB\Server\4.4\bin\mongod.exe
I am using ORACLE database in a windows environment and running a JSP/servlet web application in tomcat. After I do some operations with the application it gives me the following error.
ORA-12518, TNS: listener could not hand off client connection
can any one help me to identify the reason for this problem and propose me a solution?
The solution to this question is to increase the number of processes :
1. Open command prompt
2. sqlplus / as sysdba; //login sysdba user
3. startup force;
4. show parameter processes; // This shows 150(some default) processes allocated, then increase the count to 800
5. alter system set processes=800 scope=spfile;
As Tried and tested.
In my case I found that it is because I haven't closed the database connections properly in my application. Too many connections are open and Oracle can not make more connections. This is a resource limitation. Later when I check with oracle forum I could see some reasons that have mentioned there about this problem. Some of them are.
In most cases this happens due to a network problem.
Your server is probably running out of memory and need to swap memory to disk.One cause can be an Oracle process consuming too much memory.
if it is the second one, please verify large_pool_size or check dispatcher were enough for all connection.
You can refer bellow link for further details.
https://community.oracle.com/message/1874842#1874842
I ran across the same problem, in my case it was a new install of the Oracle client on a new desktop that was giving the error, other clients were working so I knew it wouldn't be a fix to the database configuration. tnsping worked properly but sqlplus failed with the ora-12518 listener error.
I had the tnsnames.ora entry with a SID instead of a service_name, then once I fixed that, still the same error and found I had the wrong service_name as well. Once I fixed that, the error went away.
If from one day to another the issue shows for no apparent reasons, add these following lines at the bottom of the listner.ora file. If your oracle_home environment variable is set like this:
(ORACLE_HOME = C:\oracle11\app\oracle\product\11.2.0\server)
The lines to add are:
ADR_BASE_LISTENER = C:\oracle11\app\oracle\
DIRECT_HANDOFF_TTC_LISTENER=OFF
I had the same problem when executing queries in my application. I'm using Oracle client with Ruby on Rails.
The problem started when I accidentally started several connections with the DB and didn't close them.
When I fixed this, everything started to work fine again.
Hope this helps another one with the same problem.
I experienced the same error after upgrading to Windows 10. I solved it by starting services for Oracle which are stopped.
Start all the services as shown in the following image:
I had the same issue. After restarting all Oracle services it worked again.
same problem encountered for me.
And from oracle server listener log, can see more information.
and I found that the SERVICE_NAME is not match the tnsnames.ora configured Service name. so I changed the application's data source configuration from SID value to Service_NAME value and it fixed.
23-MAY-2019 02:44:21 * (CONNECT_DATA=(CID=(PROGRAM=JDBC Thin Client)(HOST=__jdbc__)(USER=XXXXXX$))(SERVICE_NAME=orclaic)) * (ADDRESS=(PROTOCOL=tcp)(HOST=::1)(PORT=50818)) * establish * orclaic * 12518
TNS-12518: TNS:listener could not hand off client connection
TNS-12560: TNS:protocol adapter error
TNS-00530: Protocol adapter error
64-bit Windows Error: 203: Unknown error
I had the same issue in real time application and the issue gone by itself next day. upon checking, it was found that server ran out of memory due to additional processes running.
So in my case, the reason was server run out of memory
first of all
check the listener log
check the show parameter processes vs select count(*) from v$processes;
increase the process, it may require SGA increase
;
I have a BizTalk 2013r2 Standard Edition application server with CU7 installed. The BizTalk databases are hosted on a separate Sql Server 2014 server. This setup has been working fine for many months - until today! A colleague used the BizTalk admin console to make a change to the address BizTalk uses to the reach the SMTP server, by selecting Platform Settings\Adapters\SMTP\\properties.
After making this change, on attempting to refresh the BizTalk Admin Console, the following error is displayed:
From what I've googled, it seems this may be due to some corruption in the SSO database. I have a backup of the SSO database, and a backup of the SSO key along with the password. Before restoring the backup of the SSO database, I wanted to check that I would be able to restore the key, so I ran ssoconfig -restoreSecret from the command line. I was prompted to enter the password. If I intentionally enter the wrong password then it tells me the password is incorrect. However, if I enter the correct password then it displays the message "BAD DATA".
Although the BizTalk admin console is currently unusable, thankfully the BizTalk host instance continue to run and messages are being processed as expected.
Can anyone please suggest why I'm getting the "BAD DATA" message, or perhaps a work-around in order to solve the problem?
I had this problem again and blogged about it at BizTalk WinMgt error solution. As Colin says the hard part is identifying the corrupt handler. It is probably the SMTP send handler but you should check this using WBEMTEST first. I found this link helpful on using WBEMTest. The parameter is incorrect (WinMgt)" error when refreshing the BizTalk Group in BizTalk Administration Console
In my case a quick fix to bring the BizTalk Administration Console back to life was to hack the database. N.B. This probably won't be supported by MS. In my case it was the FTP send handler that screwed up. So I ran
USE [BizTalkMgmtDb]
GO
DECLARE #return_value int
EXEC #return_value = [dbo].[adm_SendHandler2_Delete]
#AdapterName = N'FTP',
#HostName = N'Sending32'
SELECT 'Return Value' = #return_value
GO
At this point the BizTalk Administration console came back to life. In my case it worked because I was creating a new handler but in your case you just edited it. It will take all your SMTP handling out.
I then fixed the corruption using the BizTalk Administration console.
In my case I had to set every FTP receive and send adapter temporarily to a FILE adapter.
I then deleted the FTP adapter and then re-added it. Finally I reset the all the change receive and send location from FILE back to FTP.
This was all very scary on a live system.
Finally I believe that this is bug in BizTalk 2013 R2 because I've seen it happen on 2 systems and now I have heard that the same thing happened to you.
The WinMgt error happens when one of the Adapters setting has gotten itself corrupted. See WinMgt error when refreshing Group Hub
Removing and re-adding the adapter to the host usually fixes it. The trick of course is identifying which Adapter / Host, I would start with the SMTP adapter in your case.
My Sql developer was working fine from long time, suddenly from yesterday when i am trying to reconnect it is giving me following error:-
Status : Failure -Test failed: IO Error: Got minus one from a read call, connect lapse 62991 ms., Authentication lapse 0 ms.
Things I tried to solve the issue:-
Made corresponding changes in sqlnet.ora , listener.ora and tnsnames.ora files
Checked is there are too many open connections to the database service.
Restarted ORACLE service and listener
Firewall related changes
Reinstalled ORACLE
In my case the issue, it is due to a malware. Whenever i am trying to connect to DB port, it was automatically getting changed by malware.
You can also identify the problem by using lsnrctl status command, for further information. You can also see the log file of listener.
Run a full scan on your machine and restart listener, hope that helps.
After upgrade our IBM System i (aka i5/OS or AS/400) from V5R4 to V7R1, one of our applications that connect to DB2 using ODBC fails with the following error:
Error Code: 69899
SQLSTATE: S1000
[IBM] [System i Access ODBC Driver] [DB2 for i5/OS] PWS0005
Error occurred in the database host server code.
The symptoms are:
In a While / Wend loop a CURSOR is declared, then opens, do fetch(s) and close.
If at any iteration the cursor does not retrieve any rows, in the following iteration the error occurs after declaring the cursor (with a different SQL query) when you try to open it.
First we updated the ODBC driver to the latest version available, but the problem persists.
Because we needed an urgent solution, I solved the problem by making a pre-select to determine if the cursor will return rows, otherwise skip that iteration, this solves the problem for now but does not seem a very elegant solution.
Any idea how to get more information about the error that occurs on the host?
Thank you very much in advance.
Generally speaking, if an error occurs in the server side code, you should call IBM support and report it. They'll ask if you're on the latest cume and probably the latest database group PTFs.
The server runs the ODBC connexion in a job called QZDASOINIT. Since there are probably many connexions to the system, there are probably many QZDASOINIT jobs. To find yours, go to a terminal session and WRKOBJLCK MYPROFILE *USRPRF. You'll be presented with a list of jobs running with your user profile. At least one of them will be the QZDASOINIT job you're looking for. Use option 5 to look at the job, then option 10 to see the job log. Press F10 to see the detailed messages and F18 to go to the bottom (most recent) entries.
If the error was so severe that the server job terminated abnormally, there won't be a lock on your user profile. Instead, go to the spooled job log by using WRKSPLF.
IBM have been logging some SQL internal errors since V5R4. select * from qrecovery.qsq901s; to see any SQLCODE -901 errors.
Make sure that you have installed the latest fix pack for the latest version of System I Access
I've had this error before and it was caused by a syntax error in the connection string. It was a setting that was insignificant in older versions of the OS and more significant in newer versions, but did not cause the connection itself to fail so it was hard to track down.
For example: Port Number:8471 had a spelling mistake and was Porte Number:8471 hard to spot but once found, it fixed the problem for me. Basically everything past this part of the connection got ignored.
Wanted to add another solution to this problem. The SQL Packages that exist on your system get corrupted after/and or during upgrades. You MUST delete these packages after an upgrade. This will get rid of the old packages and will allow the system to recreate the packages at the new OS version level. When deleting SQL packages some connections/jobs may have locks on those packages so you might have to shut host services down. Use the DLTSQLPKG command to do the delete. In v7r2 and higher there are some additional steps to do as IBM changed somethings when it comes to packages you can find the info here http://www-01.ibm.com/support/docview.wss?uid=nas8N1015556
Or tell your ODBC/JDBC/.Net Data adapter/provider to not use packages. This is probably less desirable as there are performance benefits to packages.