How to remove unwanted short time signal Simulink - matlab

I want to remove a unwanted signal that occurs for 0.02sec. For example...i have a continuous signal with value 1. For a reason i become in some cases a signal with any value (+ or -) for max 0.02sec. After that I become again the value 1. Is it possible to remove this unwanted signal?
I will be very thankful for any help!
With best regards

You can debounce your signal using sample and hold as follows:
Every time a value change is detected in the input signal, start a counter and set the output to the original (pre-changed) input value for a number of cycles that you specify. After the waiting period is over, set the output value back to the input value. If the input remains at the new value after the wait period is over, then the output will assume the new value. Otherwise it will retain the original value after the input has settled to its original value and held it for the wait duration.
This can be modeled in Simulink with a combination of 'detect change' and 'switch' blocks.

Related

How to store a specific time that a signal value is changed in another parameter in Matlab simulink?

I have two Matlab function blocks that one is producing zero signal for the other. I want to store the exact time that signal changes to one in another parameter in order to use it elsewhere.
How can I do it?
This type of functinality is achieved using a Triggered Subsystem, as per the image below,
The output of the trigger block will take on value of the input (which in this case is the simulation time) every time the trigger signal rises. Look at the parameters of the Trigger block inside the subsystem for other options such as falling edge, or both edge, triggering.

how to detect 2nd crossing to point simulink

How to detect the 2nd falling crossing when it reaches the 2nd point. The signal will rise again after the 2nd crossing and then repeats.
Each time the signal falls at 20(2nd time) i want to capture it via relational block like the output signal in the image
Input Signal:
Model:
Output
There are multiple ways this could be done. One approach is to create a triggered counter, using a Triggered Subsystem, with the counter resetting itself if the count tries to go above 2.
An example of this is shown below. The trigger is generated by comparing your input to a constant (in this case 20) and incrementing the counter based on a rising edge of that trigger. Initialize the counter to 1, then either
increment the counter if the count value is currently less than 1.
reset the counter to 1 if the counter is already at 2.
In this example the counter resets every second crossing of the threshold.
If data typing is important this could also be done using logical/boolean values (i.e. True and False), rather than the 1 and 2 used in the example.
Using the answer above by Phil, i was able to create my version without using triggered subsystem
Sample answer

Is it possible to stop a Simulink simulation when a certain condition is met?

Assume that you have a Simulink simulation where a certain signal is first positive and after some time t in a given interval, it becomes negative. Your goal is to find the zero-crossing.
A first approach would be to plot the signal over the given interval, save it and calculate the zero-crossing.
When repeating this simulation numerous times for varying parameters, it would be beneficial to be able to stop the simulation after the signal has become negative. Then there is already enough information for the calculation of the zero-crossing in Matlab. How could you do that?
Yes, use the Stop Simulation block with the appropriate logical input to the block:
You can use an if / else block to control the flow in the Simulink model. In the if / else block, you can choose the condition if u > 0, continue as normal if it's true, and use the else-option to bypass the rest of the flow you would otherwise run. For instance jump directly to the scope.
Another ways:
You can use Hit Crossing Block in Simulink to find time at the moment of hitting zero.
Another way - use any Trigger or Resettable system. It detects the zero crossing too. For example: this question at SO.
Of course you can also use User Defined function to detect zero crossing by your hand and do whatever you want with the signal at the same time.
About making a lot of simulations and then stops:
you can use Check Upper Static Bound for automatically stops simulation at the moment when zero will be crossed in nth time. For example:
I set upper bound = 10 for this block and this stops at 10th crossing.
There are a lot of ways to save function values in this points or just array of times but this is an another question :)

Variable transport delay using time after threshold has been reached in Simulink

In Simulink how can I delay the transport block to the exact time of when a certain threshold has been reached?
Basically I have an S-function which switches to an alternate input source, a sine wave, after a certain value has been reached. As soon as the switch occurs I want to start the sine wave. For that I need to delay the wave generation until the switch occurs.
How can I send that time to the Variable transport delay block?
Maybe you can try this way:
you need Variable Integer Delay for example. It changes delay to what you need. Calculate needed value of delay you can in User Defined Function, route to it your threshold value and current time and all other values you need.
Hope i understood your question correctly!

Simulink: How to convert event based signal with zero duration values to a time based signal without losing information

I have a matlab function block (which is not relevant) whose input is his previous output (loop). For example, if in a sample period the output is X, his input in the next sample period will be X, and so on.
This image shows a simplification of my simulation. I initialize the input of my function for the first loop.
The problem is that matlab functions recieves an event based signal from de initialization block in the first sample period (zero-duration), which I must convert to a timed based signal (so I can apply the unit delay that avoids an inifite loop, and allows to generate the next input as explained before). So, when I do so, I lose the information contained in the event-based signal (due to the zero-duration values) and the loop does not work.
If there was a way to intialize the loop in the time-based domain (green part of the image) so, in the first sample time, it is not a zero-duration signal, it would avoid the problem.
Is there any way to do so? Or, a different approach for this problem?
Two approaches come to mind
The initial condition can be set in the Unit Delay block, so it's not clear from your simplified example why you need the specific Initialization block.
You could just use a persistent variable inside the MATLAB Function block to maintain the state from one execution of the block to the next (noting that since it is event driven the block may not get called at every time step, only at each event triggger).